Light-Load Power Supply for Railway Traction Inverter Testing
A 1,500 VDC railway traction inverter test supply (10–20 kW typical; 24 kW peak) with independent battery simulation, SCADA supervision, and safety interlocking.

- Delivery year
- 2025
- Region
- Indonesia
- Application
- Post-assembly functional and routine testing of railway traction inverters (VVVF/propulsion converters) at production test facilities.
NSAD developed a transformer-rectifier power supply system in 2025 for post-assembly functional verification and selected routine testing of railway traction inverters (VVVF/propulsion converters). It provides a nominal 1,500 VDC main output for light-load testing and a separate 110 VDC auxiliary output to simulate the onboard battery supply.
Engineering Challenge
Unlike a fixed test installation, this project required a high-voltage power supply that could be relocated within a production testing facility for post-assembly checks of railway traction inverters. The central challenge was combining mobility with a nominal 1,500 VDC light-load test output, an independent 110 VDC onboard battery-simulation supply, and integrated monitoring, protection, and safety interlocking. Integrating these functions into a caster-mounted cabinet weighing approximately 1,200 kg required careful attention to equipment layout, positioning, and safe operation.
NSAD Solution
NSAD developed a transformer-rectifier system with a 25 kVA nominal main transformer rating and a 380 VAC, three-phase, 50 Hz input. The nominal 1,500 VDC main output operates at a typical power of 10–20 kW, with a peak output capability of 24 kW.
A separate 3 kVA, 220 VAC single-phase input supplies a regulated 110 VDC, 2 kW auxiliary output for onboard battery-supply simulation during inverter testing.
The system integrates NSAD’s MRCU-3U controller platform, 10 kHz monitoring and protection sampling, safety interlocking, SCADA supervision, and RS-485/CANopen communication interfaces.

Delivery and System Integration
The equipment is housed in a mobile cabinet on caster wheels, measuring 1.6 × 0.5 × 1.6 m (W × D × H) and weighing approximately 1,200 kg. The system supports post-assembly functional verification and selected routine testing activities referencing IEC 61287-1.
Technical Highlights
- Main AC input
- 380 VAC, three-phase, 50 Hz
- Main transformer nominal rating
- 25 kVA
- Nominal main DC output voltage
- 1,500 VDC
- Typical main DC operating power
- 10–20 kW
- Peak main DC output power
- 24 kW
- Independent auxiliary AC input
- 220 VAC, single-phase, 3 kVA
- Auxiliary DC output
- 110 VDC / 2 kW
- Power conversion configuration
- Transformer-rectifier system
- Monitoring and protection sampling rate
- 10 kHz
- Embedded control platform
- NSAD MRCU-3U