Light-Load Power Supply for Railway Traction Inverter Testing

A 1,500 VDC railway traction inverter test supply (10–20 kW typical; 24 kW peak) with independent battery simulation, SCADA supervision, and safety interlocking.

Three-quarter front view of the NSAD light-load power supply cabinet on caster wheels.
Delivery year
2025
Region
Indonesia
Application
Post-assembly functional and routine testing of railway traction inverters (VVVF/propulsion converters) at production test facilities.
  • Railway Testing
  • Transformer Rectifier
  • Power Electronics
  • Traction Power Simulation
  • SCADA

NSAD developed a transformer-rectifier power supply system in 2025 for post-assembly functional verification and selected routine testing of railway traction inverters (VVVF/propulsion converters). It provides a nominal 1,500 VDC main output for light-load testing and a separate 110 VDC auxiliary output to simulate the onboard battery supply.

Engineering Challenge

Unlike a fixed test installation, this project required a high-voltage power supply that could be relocated within a production testing facility for post-assembly checks of railway traction inverters. The central challenge was combining mobility with a nominal 1,500 VDC light-load test output, an independent 110 VDC onboard battery-simulation supply, and integrated monitoring, protection, and safety interlocking. Integrating these functions into a caster-mounted cabinet weighing approximately 1,200 kg required careful attention to equipment layout, positioning, and safe operation.

NSAD Solution

NSAD developed a transformer-rectifier system with a 25 kVA nominal main transformer rating and a 380 VAC, three-phase, 50 Hz input. The nominal 1,500 VDC main output operates at a typical power of 10–20 kW, with a peak output capability of 24 kW.

A separate 3 kVA, 220 VAC single-phase input supplies a regulated 110 VDC, 2 kW auxiliary output for onboard battery-supply simulation during inverter testing.

The system integrates NSAD’s MRCU-3U controller platform, 10 kHz monitoring and protection sampling, safety interlocking, SCADA supervision, and RS-485/CANopen communication interfaces.

Light load infographics

Delivery and System Integration

The equipment is housed in a mobile cabinet on caster wheels, measuring 1.6 × 0.5 × 1.6 m (W × D × H) and weighing approximately 1,200 kg. The system supports post-assembly functional verification and selected routine testing activities referencing IEC 61287-1.

Technical Highlights

Main AC input
380 VAC, three-phase, 50 Hz
Main transformer nominal rating
25 kVA
Nominal main DC output voltage
1,500 VDC
Typical main DC operating power
10–20 kW
Peak main DC output power
24 kW
Independent auxiliary AC input
220 VAC, single-phase, 3 kVA
Auxiliary DC output
110 VDC / 2 kW
Power conversion configuration
Transformer-rectifier system
Monitoring and protection sampling rate
10 kHz
Embedded control platform
NSAD MRCU-3U